Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/23/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADDRESS ON SERVICE PANEL 2) MIXED BREAKER TYPES IN PANEL 3) HAZARDOUS WIRING ADDED CIRCUIT TO PANEL NOT TO CODE 4) SEAL KNOCKOUTS IN PANEL 5) SEAL UNUSED OPENINGS DEAD FRONT 6) PROVIDE WEATHERED OUTLETS AT COOLERS 7) HAVE QUALIFIED ELECTRICIAN CLEAN UP WORK TO SERVICE 8) MISSING COVER PLATES LAUNDRY 9) PROVIDE COMBUSTION RELIEF WATER HEATER TPR RELIEF LINE TO EXTERIOR 10) SMOKE ALARM HALLWAY 11) GFCI PROTECT BATH OUTLET OR REMOVE 12) 2 WIRE OUTLETS AND 2 WIRE WITH GROUND MIXED THROUGHOUT 13) OMIT WINDOW A/C UNIT 14) AT LEAST ONE WINDOW EACH BEDROOM MUST WORK FOR EMERGENCY EGRESS |