Permit: T10EL02149

Parcel: 129040310


Addresses:

2001 E 9TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
09/28/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
1) SECOND UNIT DISCONNNECTED AND WIRING ABANDONED
09/17/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUNDED RECEPTS ON UNGROUNDED SYSTEM
2) EXPOSED ROMEX IN CLOSET, SHOULD BE IN RACEWAY, OR COVERED WITH DRYWALL
3) SMOKE DETECTORS REQUIRED IN HALLWAY AND BEDROOM
4) GFI PROTECTED RECEPTS REQUIRED IN KITCHEN COUNTERS AND BATHROOM
5) RECEPT BOX AT BACK DOOR HANGING OUT OF WALL
6) OVERHEAD SPAN TO APT IN BACK NOT TO CODE PER 230-240 NEC. REQUIRES 8' CLEARANCE ABOVE ROOF
7) SERVICE BOTH STRUCTURES TO BE GROUNDED PER 250 NEC
8) GENERAL WIRING AT APT NOT TO CODE, HAVE EXPOSED AND GROUNDED WIRING THROUGHOUT-OBTAIN THE SERVICES OF A LICENSED OR QUALIFIED ELECTRICIAN TO CORRECT