Permit: T10EL02075

Parcel: 138091160

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T10EL02075

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/15/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/14/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BACK PORCH LIGHT NEEDED BY CODE FOR EGRESS
2) ONLY ONE CONDUCTOR UNDER SCREW TERMINAL AND RECEPTS
3) FINISH #3 PREVIOUS INSPECTION
09/07/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXTENSION CORD WIRING AT WATER HEATER CLOSET NOT ALLOWED
2) BACK PORCH LIGHT BROKEN
3) PLEASE VERIFY KITCHEN CIRCUITS FOR GFCI 210.52 & 210.8
4) MISSING LIGHT/FAN IN BEDROOM AND SERVICE CABLE TO BOX & FILL UNUSED OPENING
5) MISSING COVER PLATE
6) RECEPTS TO FAR BACK IN WALLS
7) MISSING LIGHT/FAN LIVING ROOM AND DINING ROOM
8) OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN