Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/30/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOT CHECK OF OUTLETS AFTER POWER RESTORED 2) PROVIDE SAFE ACCESS TO ROOF 3) LABEL ALL CIRCUITS DEAD FRONT |
|
| 09/22/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL ELECTRICAL AND GAS AT ROOF TOP NOT TO CODE. SECURE GAS LINES PER CODE. WEATHERED FITTINGS NEEDED AT PORCH ALSO 2) ADDED PLUMBING AT LAUNDRY EXTERIOR NOT TO CODE. NO TRAPS OR VENTS 3) MAIN DROP WITHIN 12" OF REAR PORCH. RELOCATE SERVICE AND RAISE RISER. OMIT PORCH OR STORAGE 4) WATER HEATER WIRING NOT TO CODE TPR LINE CANNOT BE PVC 5) POSSIBLE ILLEGAL ADDITION AT WEST MISSING OUTLETS PER CODE. ROOM REQUIRES HEAT SOURCE 6) GFCI PROTECT KITCHEN OUTLETS. MISSING OUTLET AT PENINSULA 7) RELOCATE SMOKE ALARMS WITHIN 36" FORCED AIR REGISTERS 8) SEE NOTES FROM INSPECTION 9/20/10 9) ALL BEDROOM WINDOWS MUST OPERATE PROPERLY FOR EGRESS |
|
| 09/20/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) FINISH ITEMS 2,3,6,7,9,10,11 & 12 2) UNIT IS OCCUPIED WITHOUT POWER |
|
| 09/16/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* LOCKED NO ACCESS LEFT A MESSAGE WATER HEATER PERMIT NOT OBTAINED AT THIS TIME |
|
| 09/09/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROPERLY SPLICE AND TERMINATE GROUNDS AT RECEPTS 2) GROUNDED RECEPTS ON NON GROUNDED CIRCUITS 3) SMOKE DETECTORS NEEDED FOR BEDROOOMS 4) MISSING BATH LIGHT 5) EXPOSED NM CABLE BACK PORCH 6) USE APPROVED PARTS FOR ELECTRIC 7) FILL UNUSED OPENINGS AT PANEL 8) MISSING DEAD FRONT COVER 9) WIRING TO LEFT OF PANEL NOT TO CODE 10) WILL NEED PERMIT FOR WATER HEATER INSTALLATION (MISSING W/H) 11) WIRING TO REAR SHED NOT TO CODE 12) OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN |