Permit: T10EL02056

Parcel: 120030070


Addresses:

1050 W LINCOLN ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/06/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/30/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOT CHECK OF OUTLETS AFTER POWER RESTORED
2) PROVIDE SAFE ACCESS TO ROOF
3) LABEL ALL CIRCUITS DEAD FRONT
09/22/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL ELECTRICAL AND GAS AT ROOF TOP NOT TO CODE. SECURE GAS LINES PER CODE. WEATHERED FITTINGS NEEDED AT PORCH ALSO
2) ADDED PLUMBING AT LAUNDRY EXTERIOR NOT TO CODE. NO TRAPS OR VENTS
3) MAIN DROP WITHIN 12" OF REAR PORCH. RELOCATE SERVICE AND RAISE RISER. OMIT PORCH OR STORAGE
4) WATER HEATER WIRING NOT TO CODE TPR LINE CANNOT BE PVC
5) POSSIBLE ILLEGAL ADDITION AT WEST MISSING OUTLETS PER CODE. ROOM REQUIRES HEAT SOURCE
6) GFCI PROTECT KITCHEN OUTLETS. MISSING OUTLET AT PENINSULA
7) RELOCATE SMOKE ALARMS WITHIN 36" FORCED AIR REGISTERS
8) SEE NOTES FROM INSPECTION 9/20/10
9) ALL BEDROOM WINDOWS MUST OPERATE PROPERLY FOR EGRESS
09/20/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) FINISH ITEMS 2,3,6,7,9,10,11 & 12
2) UNIT IS OCCUPIED WITHOUT POWER
09/16/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
LOCKED NO ACCESS LEFT A MESSAGE
WATER HEATER PERMIT NOT OBTAINED AT THIS TIME
09/09/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROPERLY SPLICE AND TERMINATE GROUNDS AT RECEPTS
2) GROUNDED RECEPTS ON NON GROUNDED CIRCUITS
3) SMOKE DETECTORS NEEDED FOR BEDROOOMS
4) MISSING BATH LIGHT
5) EXPOSED NM CABLE BACK PORCH
6) USE APPROVED PARTS FOR ELECTRIC
7) FILL UNUSED OPENINGS AT PANEL
8) MISSING DEAD FRONT COVER
9) WIRING TO LEFT OF PANEL NOT TO CODE
10) WILL NEED PERMIT FOR WATER HEATER INSTALLATION (MISSING W/H)
11) WIRING TO REAR SHED NOT TO CODE
12) OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN