Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T10EL02047
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/12/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) RECEIVED LETTER FOR CODE COMPLIANCE PERMIT #T10CM03095 |
|
10/04/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STILL HAVE OPEN LIGHT FIXTURE IN LAUNDRY. HAVE OPEN JUNCTION BOX IN LAUNDRY 2) SMOKE DETECTORS NOT INSTALLED PROPERLY TO BE MINIMUM 3' FROM HEATING/AC VENT AND MINIMUM 4" FROM CORNERS |
|
09/01/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 2) INSTALL MISSING PLATES 3) INSTALL SMOKE DETECTORS IN BEDROOMS, PLEASE READ INSTRUCTIONS 4) RECEPT HANGING OUT OF WALL 5) RECEPT BACK TO FAR FROM PLATE 6) REPLACE BROKEN PLATES 7) OPEN JUNCTION BOX MSTR CLOSET 8) CLOTHES CLOSET LIGHTS TO BE 100 PERCENT ENCLOSED OR REMOVED 9) OPEN LIGHT FIXTURE LAUNDRY 10) RESCHEDULE ONLY WHEN 100 PERCENT COMPLETE 11) BATHROOM RECEPTS TO BE GFI PROTECTED |