Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/16/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
10/06/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS 2) GFCI PROTECT KITCHEN OUTLETS AND BATH OUTLETS 3) PROVIDE COMBUSTION RELIEF LAUNDRY ROOM FOR WATER HEATER 4) SMOKE ALARM ALL BEDROOMS 5) PROVIDE PROOF OF ALL ADDITIONS AND PORCHES AT REAR ON PROPERTY LINE |
|
08/03/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING KITCHEN GFI'S 2) NEED SMOKE DETECTORS HALL AND BEDROOMS-INSTALLED ONES APPEAR INOPERATIVE 3) MISSING COVER PLATES 4) NEED BATHROOM GFCI'S 5) IMPROPER WIRING IN LAUNDRY ROOM 6) EXPOSEDF NM CABLE ON BACK PORCH 7) MISSING BACK PORCH LIGHT AND DINING LIGHT 8) MISSING BATHROOM SINKS 9) MISSING WATER HEATER 10) OBTAIN THE SERVICES OF A QUALIFIED WORKMAN |