Permit: T10EL01834

Parcel: 115010370


Addresses:

2326 N FLORES DR

Inspection Status: Partial Approval

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/30/2010 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) WIRING TO AND AT CARPORT NOT TO CODE, EXPOSED ROMEX, SPLICES AND LIGHT FIXTURES WIRED WITHOUT BOXES
2) ALL SERVICE DISCONNECT SWITCHES DBL LUGGED
3) OUTSIDE RECEPTS NEED GFI PROTECTION
4) COOLER WIRING APPEARS TO BE SUN ROTTED
5) SMOKE DETECTORS REQUIRED IN BEDROOMS
6) SUPPORT CONDUITS/CABLE AT BACK PORCH SERVICE EQUIPMENT WILL NEED SERVICE UPGRADE
7) ALSO APPEARS TO BE VANDALIZED WILL CALL APPLICAN TO NOTIFIY