Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2010 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 07/14/2010 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS VISIBLE FROM STREET 2) RECEPTS ABOVE KITCHEN COUNTERS REQUIRE GFCI PROTECTION 3) RECEPTS IN BATHROOM REQUIRE GFCI PROTECTION 4) ALL SLEEPING ROOMS AND HALLWAYS LEADING TO SLEEPING ROOMS REQUIRE SMOKE DETECTORS. INSTALL PER MANUFACTURES INSTRUCTIONS 5) REPAIR COLLAPSING SHEETROCK SOFFIT IN HALLWAY 6) VERIFY PERMIT FOR 220 DRYER BRANCH CIRCUIT 7) LABEL SERVICE PANEL DIRECTORY 8) REMOVE AND REPLACE CLOTHES WASHER RECEPT CURRENTLY HAS MULTI PORT-INSTALL DUPLEX TYPE 9) PROVIDE ALL MISSING RECEPT COVERS |