Permit: T10EL01663

Parcel: 13012237B


Addresses:

3534 E 32ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
11/04/2010 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
07/14/2010 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST ADDRESS VISIBLE FROM STREET
2) RECEPTS ABOVE KITCHEN COUNTERS REQUIRE GFCI PROTECTION
3) RECEPTS IN BATHROOM REQUIRE GFCI PROTECTION
4) ALL SLEEPING ROOMS AND HALLWAYS LEADING TO SLEEPING ROOMS REQUIRE SMOKE DETECTORS. INSTALL PER MANUFACTURES INSTRUCTIONS
5) REPAIR COLLAPSING SHEETROCK SOFFIT IN HALLWAY
6) VERIFY PERMIT FOR 220 DRYER BRANCH CIRCUIT
7) LABEL SERVICE PANEL DIRECTORY
8) REMOVE AND REPLACE CLOTHES WASHER RECEPT CURRENTLY HAS MULTI PORT-INSTALL DUPLEX TYPE
9) PROVIDE ALL MISSING RECEPT COVERS