Permit: T10EL01608

Parcel: 135083360

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/12/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/07/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HAVE OPEN CONDUCTORS TO LIGHT FIXTURE IN LAUNDRY, NEED APPROVED WIRING METHOD
2) BATHROOM RECEPTS TO BE GFI PROTECTED, NEED TO VERIFY BREAKER AT PANEL CONTROLS-ALL BATHROOMS
3) OUTDOOR RECEPTS TO BE GFI PROTECTED
4) CLOSE OPEN KNOCKOUTS
5) INSTALL MISSING WALL PLATES
6) VERIFY GROUNDING TYPE RECEPTS AND HAVE EQUIPMENT GROUND
7) OPEN BOX IN CEILING BEDROOM
8) RE-INSTALL VENT FOR WATER HEATER