Permit: T10EL01482

Parcel: 137332310


Addresses:

5820 S LOG HILL PL

Inspection Status: Cancelled

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/26/2010 ELECTRIC - FINAL Cancelled IVRS - RI canceled
10/26/2010 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) LEFT MESSAGE AT 10:00 AM
06/23/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONDUIT ON SIDE OF PANEL NOT INSTALLED PER CODE
2) USE CURRENT SIZED BREAKER FOR AMPACITY ON #8 NM CABLE 334.80
3) NEED VERIFICATION OF PERMIT FOR A/C UNIT
4) MISSING LIGHT FIXTURES IN GARAGE
5) RE-INSTALL KITCHEN GFCI AND PROVIDE ARC SHIELDS AT ALL RECEPTS ON TILE
6) RE-INSTALL HALL SMOKE DETECTOR AND NEED SMOKE DETECTORS IN BEDROOMS-INSTALL PER INSTUCTIONS
7) RE-INSTALL DINING ROOM RECEPT INTO WALL
8) MISSING FURNACE-WILL NEED A PERMIT FOR REPLACEMENT
9) EXPOSED CONDUCTORS STICKING OUT OF GROUND BACK PORCH
10) NEED PROPER QUICK RELEASE HARDWARE FOR WROUGHT IRON WINDOWS BEDROOMS
11) VERIFY PERMIT FOR FRONT ENTRY ADDITION-IMPENDING EGRESS FOR BEDROOM
06/21/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
1) LOCKED-NO ACCESS
2) PERSON ANSWERING PHONE AT 808-8105 DID NOT HAVE ACCESS