Permit: T10EL01437

Parcel: 120051390


Addresses:

4524 S 19TH AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/30/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/26/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RECEPTS MORE THAN 1/4" #4 PREVIOUS
2) SUB PANELS (BREAKER) FILL UNUSED OPENINGS, SECURE NM CABLES, VERIFY GROUNDING EQUIPMENT AND IDENTIFY UNINSULATED NEUTRAL (FUSE) SEPERATE GROUNDS AND NEUTRALS, VERIFY CONDUCTOR AMPACITY TO FUSE SIZE, MULTIPLE TERMINATIONS
3) OPEN EXPOSED CONDUCTORS BY WATER HEATER
06/16/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
1 - LIGHT ABOVE SERVICE NOT TO CODE
2 - MISSING WEATHER PROOF COVER ON RECEPTACLE BELOW PANEL
3 - PROPERLY SEAL ENTRANCES ABOVE CURRENT CARRING PARTS WITH AN APPROVED DEVICE AT SERVICE
4 - RECEPTACLES IN WALL MORE THAT 1/4" BOX TO SURFACE (UP TO 1" BACK)
5 - SMOKE DETECTOR NEEDED IN BEDROOM - INSTALL PER INSTRUCTIONS
6 - PROPERLY BLANK JUNCTION BOXES
7 - PROPERLY WIRE HOOD - A CONNECTOR IS ALSO NEEDED
8 - RECEPTACLE NOT ACCESSIBLE BELOW BACKSPLASH
9 - SUB PANEL NOT WIRED TO CODE
10 - VERIFY PERMITS FOR ADDITION
11 - VERIFY PERMITS FOR WATER HEATER - COMBUSTION RELIEF & PRESSURE RELIEF