Permit: T10EL01335

Parcel: 125113690


Addresses:

3762 E 3RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/09/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/07/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SERVICE PANEL HAS OPENINGS IN DEAD FRONT. FILL IN APPROVED MANNER
2) REPLACE MISSING COVER ON 90 DEGREE BEND BELOW SERVICE PANEL
3) ALL EXTERIOR RECEPTS REQUIRED TO BE GFCI PROTECTED (ONE BELOW SERVICE AND ONE ON REAR PATIO)
4) ALL RECEPTS ABOVE KITCHEN COUNTERS NEED TO BE GFCI
5) ALL RECEPTS ABOVE BATHROOM VANITIES NEED TO BE GFCI
6) FIXTURE COVER MISSING IN KITCHEN
7) ALL SLEEPING ROOMS AND HALLWAYS LEADING TO SLEEPING ROOM REQUIRE SMOKE DETECTORS