Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T10EL01306
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/04/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
06/02/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLEAN EXCESS PAINT AND FOREIGN MATERIAL FROM DEVICES 2) KITCHEN RECEPTS TO BE GFCI PROTECTED 3) SMOKE DETECTOR NEEDED IN HALL 4) IDENTIFY SERVICE WITH PERMANENT METAL LABEL 5) LABEL BREAKERS 6) MAIN BACK FEED BREAKER TO HAVE MANUFACTURES HOLDOWN 7) MISSING WATER AND GAS BOND |