Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/21/2010 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) PROVIDE UNGROUNDED PLUGS 2) PROVIDE SWITCH AND OUTLET COVERS 3) LABEL SUB-PANEL |
|
| 06/22/2010 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/21/2010 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/01/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIRING TO LIGHT POLES IN BACKYARD NOT TO CODE, ALSO SECURITY LIGHT FRONT AND BACK 2) GFI PROTECTED RECEPTS REQUIRED IN KITCHEN AND BATHROOMS 3) SMOKE DETECTORS IN HALLWAY AND BEDROOMS 4) COOLER RECEPT ON ROOF TO HAVE W/P BOX AND COVER 5) NEED ACCESS IN HOUSE AND BACK STORAGE, CHECK FOR EXPOSED WIRING, RECALL INSPECTION WHEN CORRECTED 6) WORK TO BE DONE BY LICENSED OR QUALIFIED ELECTRICIAN |