Permit: T10EL01050

Parcel: 140061540


Addresses:

3713 E FRANKFORT SV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/04/2010 ELECTRIC - FINAL Approved
06/02/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ELECTRICAL WIRE IN WALL AS NOTED #2 PREVIOUS INSPECTION
2) BREAKERS NOT LISTED PER PANEL MANUFACTURE #4 PREVIOUS
3) RISER SUPPORTS NOT PROPERLY INSTALLED
06/01/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOCKED, NO ACCESS-NO KEY UNDER ROCKS
2) NO PERMITS FOR KITCHEN WIRING OR SERVICE
3) A REFEE MAY BE ASSESED
05/07/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BOXES BEHIND 2ND LAYER DRYWALL MORE THAN 1/4" 314.20, ALSO USE APPROVED HARDWARE FOR DEVICES-NOT DRYWALL SCREWS
2) PLEASE VERIFY PERMIT FOR NEW WIRING IN KITCHEN WALL , CEILING, LAUNDRY ROOM AND NEW ADDITION
3) INSTALL SMOKE DETECTORS PER INSTRUCTIONS
4) BREAKERS TO BE LISTED FOR USE BY PANEL MANUFACTURE
5) VERIFY PERMIT FOR PANEL AT SERVICE RELOCATION, RISER NOT SUPPORTED
6) OPEN ELECTRICAL BOXES
7) MISSING PLUMBING FIXTURES
8) PLEASE VERIFY PERMITS FOR NEW PORCH, SIDING TO ADDITION