Permit: T10EL01046

Parcel: 11717023C


Addresses:

88 E BROADWAY BL


Inspection Status: Approved

Inspection History: ELECTRIC - TEMPORARY SERVICE

Permit Number - T10EL01046

Inspection Description - ELECTRIC - TEMPORARY SERVICE

Inspection Status - Approved

Date Description Inspector Results Comments
05/10/2011 ELECTRIC - TEMPORARY SERVICE Approved
02/07/2011 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
02/04/2011 ELECTRIC - TEMPORARY SERVICE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
12/10/2010 ELECTRIC - TEMPORARY SERVICE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1) ONLY ONE CONDUCTOR PER LUG
2) USE APPROVED END CAPS FOR FINE STRANDED CONDUCTORS
3) IDENTIFY PHASES ON CONDUCTORS
12/08/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) MAINTAIN WORKING CLEARANCE
2) NEED LOAD CONNECTIONS
3) OK DISCONNECT LINE SIDE AND GROUNDING/BONDING
12/01/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) LABEL DISCONNECTS
2) MAINTAINING WORKING SPACE 110.26
3) BONDING JUMPER TO BE CORROSION RESISTANT 250.102 (A)
11/23/2010 ELECTRIC - TEMPORARY SERVICE Not ready for Inspection IVRS - Inspection :*
09/08/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) OK SPLICES FOR CRANE
09/01/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) OK #10 SPLICES
2) FINISH OTHER SPLICES
08/31/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) OK GROUNDING ELECTRODE CONDUCTOR TO DISCONNECT
2) OK LABELING OF EQUIPMENT
3) SPLICES STILL NOT INSTALLED
08/27/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) ? STRUCTURE DISCONNECT TO HAVE GROUNDING ELECTRODE CONDUCTOR ATTACHED 250.32 (A) & (C)
2) FINISH SPLICES
3) LABEL BREAKER AND DISCONNECT
08/26/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) SPLICES TO BE FOR WET LOCATION-SCOTCH KOTE IS LISTED FOR DRY/DAMP, NOT WET
2) GENERATOR TO BE GROUNDED TO GEC
08/25/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
1) OK PULL BOX FOR SPLICING WEST END-NOTE SPLICES TO BE FOR WET LOCATION
06/09/2010 ELECTRIC - TEMPORARY SERVICE Partial Approval IVRS - Inspection :*
06/04/2010 ELECTRIC - TEMPORARY SERVICE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*