Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/16/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SMOKE DETECTORS IN BEDROOMS NOT INSTALLED PROPERLY. TO BE MINIMUM 36" FROM VENT. TO BE INSTALLED NEAR HIGHEST PORTION OF SLOPED CEILING MINIMUM 4" DOWN TO MAX OF 12". PLEASE READ INSTALL INSTRUCTIONS 2) COMPLETE ITEM #2, 3 & 4 |
|
| 05/04/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SMOKE DETECTORS IN BEDROOMS AND HALLWAY 2) NEED GFI AND WEATHER PROOF COVER AND CONNECTORS FOR OUTLET ON OUTSIDE SOUTH EAST CORNER OF HOUSE 3) NEED WIRE NUTS FOR J-BOX BEHIND HOUSE AND K.O. SEALS AND CONNECTORS 4) NEED OUTLET UNDER KITCHEN WINDOW STRAPPED AND NEED CONNECTOR |