Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T10EL00997
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/09/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
05/04/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL MISSING WALL PLATES 2) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 3) REPLACE PAINTED OVER RECEPT 4) INSTALL SMOKE DETECTORS IN BEDROOMS 5) CLOTHES CLOSET LIGHTS TO BE 100 PERCENT ENCLOSED 6) BATHROOM RECEPTS TO BE GFI PROTECTED 7) BLANK OPEN BREAKER POSITION IN PANEL 8) OUTDOOR RECEPTS TO BE GFI PROTECTED 9) RESCHEDULE WHEN 100 PERCENT COMPLETE |