Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 07/08/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE SECONDARY ROD TO GROUND ROD SYSTEM 2) METAL ADDRESS TAG METER BASE 3) PROVIDE ACORN CLAMPS AT GROUND RODS 4) BOND GAS AND WATER METALIC LINES 5) INSPECTION FOR SERVICE UPGRADE |
|
| 02/16/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/15/2011 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/14/2011 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 01/19/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) AT LEAST ONE WINDOW EACH BEDROOM MUST OPERATE PROPERLY FOR EMERGENCY EGRESS 2) ADDITION NORTH BEDROOM NO EMERGENCY EGRESS. PROVIDE PROOF OF PERMIT ALL ADDITIONS TO NORTH SIDE OF PROPERTY 3) NOTES 2, 3, 4 12, 13 & 14 FROM PREVIOUS |
|
| 01/14/2011 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |
|
| 04/27/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS ON BLDG 2) GROUNDED RECEPTS ON NON GROUNDED CIRCUITS 3) NEED SMOKE DETECTORS IN BEDROOMS AND HALL INSTALL AS PER INSTRUCTIONS 4) VERIFY PERMIT FOR NEW WIRING TO INTERIOR 5) MISSING FIXTURES 6) MISSING CEILING IN BEDROOM 7) PROTECT BULBS IN CLOSETS 8) JUNCTION BOXES TO BE ACCESSIBLE 9) BATHROOM RECEPT TO BE GFCI PROTECTED 10) NO KITCHEN PLUMBING OR COUNTER TOPS 11) EXPOSED CABLE IN KITCHEN 12) OPEN SPLICES LAUNDRY ROOM 13) SUPPORT CONDUITS TO STRUCTURE 14) STRAP GROUNDING ELECTRODE CONDUCTOR TO STRUCTURE 15) VERIFY SERVICE UPGRADE 16) PARTIAL INSPECTION 17) UNIT IS NOT HABITABLE |