Permit: T10EL00945

Parcel: 140160980


Addresses:

1734 E MIRA LOMA PL


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T10EL00945

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/12/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/22/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP EMT WITHIN 3' OF ENTERING PANEL
2) VERIFY PERMIT FOR NEW FURNACE AND A/C UNIT
3) INSTALL MISSING WALL PLATES
4) INSTALL SMOKE DETECTORS IN BEDROOMS AND HALL
5) WIRING AT REAR PATIO TO FAN AND FLOOD LIGHT NOT TO CODE
6) KITCHEN COUNTER AND BATHROOM RECEPTS TO BE GFI PROTECTED
7) OUTDOOR RECEPTS TO BE GFI PROTECTED AND HAVE WEATHER PROOF COVERS
8) REPLACE PAINTED OVER RECEPTS
9) RESCHEDULE WHEN 100 PERCENT COMPLETE