Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T10EL00899
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/09/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
06/07/2010 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) FINISH REPAIR EXTERIOR J-BOX 2) A REFEE MAY BE ASSESED |
|
05/04/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
04/21/2010 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SWITCH COVER PLATE MISSING AT ENTRY DOOR 2) GFCI RECEPTS REQUIRED ABOVE KITCHEN COUNTERS (SEE NEXT TO SINK ON WALL WITH SWITCH) 3) GFCI RECEPT IN BATHROOM HAS TEST AND RESET BUTTONS COVERED IN PAINT-REPLACE 4) EXTERIOR J-BOX TO LEFT OF NEW SERVICE IS IN DISREPAIR AND MISSING COVER |