Permit: T10EL00874

Parcel: 132091410

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/24/2010 ELECTRIC - FINAL Approved
04/15/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SMOKE DETECTORS TO BE INSTALLED PER MANUFACTURES INSTRUCTIONS
2) GROUNDED RECEPTS ON NON GROUNDED CIRCUIT
3) PLEASE VERIFY PERMIT FOR POP OUT WINDOW AND NEW CLOSET IN ADDITION
4) MISSING COVER PLATES AND WEATHER PROOF ON BACK PORCH
5) MISSING HOOD, EXPOSED CABLE AND CONDUCTORS
6) KITCHEN RECEPTS TO BE GFCI PROTECTED
7) SECURE LIGHT FIXTURE IN CLOSET
8) ON GROUNDED CIRCUITS METAL BOXES TO BE BONDED
9) A REFEE MAY BE ASESSED