Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2011 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 03/07/2011 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/13/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIRE CEILING FAN IN CARPORT PER CODE OR REMOVE 2) INSTALL JUNCTION BOXES AT OUTDOOR LIGHT FIXTURES 3) MISSING SWITCH PLATES 4) WIRES HANGING ABOVE RANGE 5) INSTALL SMOKE DETECTORS IN BEDROOMS AND HALL 6) REPLACE PAINTED OVER RECEPTS AND DAMAGED RECEPTS 7) HAVE 2 WIRE CORDS RUNNING ABOVE CEILING, NEEDS TO BE REMOVED 8) SUB PANEL DAMAGED AND NEED TO BE REPLACED 9) IMPROPER OVERCURRENT PROTECTION ON CONDUCTORS 10) ONE NEUTRAL PER TERMINAL IN PANEL 11) SEAL OPEN BREAKER POSITIONS 12) NEED PANEL DIRECTORY 13) ELECTRIC ON ROOF APPEARS TO BE NON CODE COMPLIANT 14) TO MANY ITEMS TO LIST. STOPPED INSPECTION. HAVE QUALIFIED ELECTRICAL CONTRACTOR GO THROUGH ENTIRE HOUSE AND MADE CORRECTIONS AS NEEDED 15) RESCHEDULE WHEN 100 PERCENT COMPLETE |