Permit: T10EL00817

Parcel: 113043260


Addresses:

1001 E NAVAJO RD

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
05/27/2010 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
04/09/2010 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURITY LIGHT NOT PER CODE OUTSIDE HOUSE
2) WIRING IN CARPORT NOT TO CODE, EXPOSED SPLICES
3) EXPOSED ROMEX IN BATHROOM, KITCHEN CABINETS
4) 110V RECEPTS ARE MIXED, GROUNDED AND UNDERGROUNDED-VERIFY AND FIX
5) SMOKE DETECTORS REQUIRED IN HALL AND BEDROOMS REQUIRED
6) GFI PROTECTED RECEPTS IN BATHROOMS AND KITCHEN COUNTERS
7) CEILING FANS NOT TO CODE
8) COOLER RECEPTS NEED W/P BOX AND COVER
9) VERIFY WATER AND GAS BONDING