Permit: T10EL00799

Parcel: 131042560


Addresses:

4926 E 26TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/22/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/13/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HAVE 3 PRONG GROUNDED RECEPTS ON 2 WIRE WITH NO EQUIPMENT GROUND SYSTEM
2) IT APPEARS SERVICE WAS UPGRADED WITH NO PERMITS OR INSPECTIONS
3) OUTDOOR RECEPTS TO BE GFI PROTECTED WITH WEATHER PROOF COVERS
4) OUTDOOR SWITCHES TO HAVE WEATHER PROOF COVERS
5) REPLACE BROKEN RECEPTS AND PLATES
6) CONNECT EQUIPMENT GROUNDS TO METAL BOXES
7) HAVE EXPOSED CONDUCTORS IN LAUNDRY
8) RECEPTS IN GARAGE TO BE GFI PROTECTED
9) BOND GAS AND WATER PIPING
10) PROTECT LABELS THRU BACK OF PANEL
11) INSTALL BREAKERS LISTED FOR USE IN PANEL, NEED PANEL DIRECTORY
12) CLOSE OPEN BOXES. REMOVE EXTENSION CORDS THRU WALL
13) TO MANY ITEMS TO LIST, HAVE ELECTRICAL CONTRACTOR GO THRU ENTIRE PROPERTY AND MAKE CORRECTIONS AS NEEDED