Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/22/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/13/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HAVE 3 PRONG GROUNDED RECEPTS ON 2 WIRE WITH NO EQUIPMENT GROUND SYSTEM 2) IT APPEARS SERVICE WAS UPGRADED WITH NO PERMITS OR INSPECTIONS 3) OUTDOOR RECEPTS TO BE GFI PROTECTED WITH WEATHER PROOF COVERS 4) OUTDOOR SWITCHES TO HAVE WEATHER PROOF COVERS 5) REPLACE BROKEN RECEPTS AND PLATES 6) CONNECT EQUIPMENT GROUNDS TO METAL BOXES 7) HAVE EXPOSED CONDUCTORS IN LAUNDRY 8) RECEPTS IN GARAGE TO BE GFI PROTECTED 9) BOND GAS AND WATER PIPING 10) PROTECT LABELS THRU BACK OF PANEL 11) INSTALL BREAKERS LISTED FOR USE IN PANEL, NEED PANEL DIRECTORY 12) CLOSE OPEN BOXES. REMOVE EXTENSION CORDS THRU WALL 13) TO MANY ITEMS TO LIST, HAVE ELECTRICAL CONTRACTOR GO THRU ENTIRE PROPERTY AND MAKE CORRECTIONS AS NEEDED |