Inspection History: ELECTRIC - FINAL
Permit Number - T10EL00734
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
05/24/2010 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
05/07/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND SWITCH IN NEW BOX WITH METAL RING 2) FITTINGS TO BE FOR WET LOCATION 3) NEED LISTED MAST BRACE KIT 4) WHERE IS WATER BOND 5) PLEASE VERIFY SUNLIGHT RESISTANT MARKINGS ON SERVICE CONDUCTORS 6) NEED TO SEE JUNCTION BOX WHERE OLD MEETS NEW |
|
04/27/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED A SERVICE UPGRADE PERMIT 2) BOXES MORE THAN 1/4" BOX TO SURFACE 314.20 3) BOXE IN WALL THAT IS OPEN IS OVER FILLED AND NEEDS CONNECTOR 4) FINISH ITEMS 3, 6, 13 & 15 NOTE #16 UNIT IS NOT HABITABLE 5) CABLES TO EXTEND INTO BOX 1/4" IN KITCHEN BOXES |
|
04/01/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BURNT OUT RECEPT AT FRONT DOOR 2) MISSING COVER PLATES ALSO BROKEN PLATES 3) EXPOSE WIRING IN WALLS AND CEILING 4) OPEN BOXES 5) NEED SMOKE DETECTORS IN BEDROOMS 6) MISSING PLUMBING FIXTURES 7) GROUNDED RECEPTS ON UNGROUNDED CIRCUITS 8) FURNACE CORD DETERIORATED 9) MISSING FIXTURES 10) MISSING DEAD FRONT COVER 11) SERVICE NOT TO CODE-VERIFY UPGRADE PERMIT 12) EXPOSE M/C CABLE ON EXTERIOR 13) COVER WIRING NOT TO CODE 14) BROKEN BAKE PORCH LIGHT 15) PLEASE HAVE A QUALIFIED ELECTRICIAN PERFORM WORK 16) UNIT IS NOT HABITABLE |