Permit: T10EL00734

Parcel: 130083460


Addresses:

3471 E 28TH ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T10EL00734

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/25/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/24/2010 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
05/07/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND SWITCH IN NEW BOX WITH METAL RING
2) FITTINGS TO BE FOR WET LOCATION
3) NEED LISTED MAST BRACE KIT
4) WHERE IS WATER BOND
5) PLEASE VERIFY SUNLIGHT RESISTANT MARKINGS ON SERVICE CONDUCTORS
6) NEED TO SEE JUNCTION BOX WHERE OLD MEETS NEW
04/27/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED A SERVICE UPGRADE PERMIT
2) BOXES MORE THAN 1/4" BOX TO SURFACE 314.20
3) BOXE IN WALL THAT IS OPEN IS OVER FILLED AND NEEDS CONNECTOR
4) FINISH ITEMS 3, 6, 13 & 15 NOTE #16 UNIT IS NOT HABITABLE
5) CABLES TO EXTEND INTO BOX 1/4" IN KITCHEN BOXES
04/01/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BURNT OUT RECEPT AT FRONT DOOR
2) MISSING COVER PLATES ALSO BROKEN PLATES
3) EXPOSE WIRING IN WALLS AND CEILING
4) OPEN BOXES
5) NEED SMOKE DETECTORS IN BEDROOMS
6) MISSING PLUMBING FIXTURES
7) GROUNDED RECEPTS ON UNGROUNDED CIRCUITS
8) FURNACE CORD DETERIORATED
9) MISSING FIXTURES
10) MISSING DEAD FRONT COVER
11) SERVICE NOT TO CODE-VERIFY UPGRADE PERMIT
12) EXPOSE M/C CABLE ON EXTERIOR
13) COVER WIRING NOT TO CODE
14) BROKEN BAKE PORCH LIGHT
15) PLEASE HAVE A QUALIFIED ELECTRICIAN PERFORM WORK
16) UNIT IS NOT HABITABLE