Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/31/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 03/29/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BREAKER TO BE LISTED BY PANEL MANUFACTURE 2) EXPOSED OUTLET AND WIRING INSIDE COOLER DUCT |
|
| 03/25/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 2) BATHROOM RECEPTS TO BE GFI PROTECTED 3) INSTALL SMOKE DETECTOR IN BEDROOM 4) CHECK SMOKE DETECTOR IN LIVING ROOM IS OPERATIONAL INSTALL BATTERY 5) INSTALL MISSING SWITCH PLATE 6) INSTALL DEAD FRONT ON PANEL AND INSTALL ADDITIONAL BRANCH CIRCUIT BREAKER. HAVE TRIPLE TAP ON 1 BREAKER AND INSTALL PROPER SIZE BREAKERS 7) PROPERLY INSTALL CONNECTION ON FEEDER CABLE AT PANEL |