Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 06/29/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BACK FED BREAKERS TO BE SECURED IN PLACE BY ADDITIONAL FASTENERS NEC 408.36 (F) |
|
| 06/22/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REVISE PERMIT OR OBTAIN NEW PERMIT FOR SERVICE PANEL REPLACEMENT 2) NEED SERVICE DISCONNECT 3) INSTALL BREAKERS LISTED FOR USE IN CUTLER HAMMER PANEL 4) INSTALL MAIN BONDING JUMPER 5) BOND SERVICE RACEWAYS 6) INSTALL NEW GROUNDING ELECTRODE SYSTEM AND BOND GAS & WATER 7) PROTECT WIRES AT ENTRY TO PANEL AND SEAL OPENING WITH NON-COMBUSTIBLE MATERIAL 8) INSTALL CONNECTOR ON WIRE ENTRY TO RANGE EXHAUST 9) INSTALL ALL WALL PLATES 10) RESCHEDULE WHEN 100 PERCENT COMPLETE |
|
| 03/22/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED. 2) HAVE OPN WIRES & EXHAUST HOOD LOCATION 3) BATHROOM RECEPTACLES TO BE GFI PROTECTED 4) INSTALL LIGHT FIXTURES IN BATHROOM 5) HAVE OPEN JUNCTION BOXES IN BEDROOMS 6) SMOKE DETECTORS TO BE 36' FROM VENTS 7) MISSING LIFHT FIXTURE BACK PANELS. NEEDS JUNCTION BOX 8) OUTDOOR RECEPTACLES TO BE GFI PROTECTED NEED WEATHERPROOF COVERS TO CLOSE 9) SERVICE PANEL MISSING DEAD FRONT 10) SECURE SERVICE PANEL TO BUILDING. SECURE GROUNDING ELECTRIC CONDUCTOR TO BUILDING 11) RESCHEDULE WHEN 100% COMPLETE. |