Permit: T10EL00569

Parcel: 138141320


Addresses:

201 W BILBY RD

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/24/2011 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/22/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
06/06/2011 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
06/01/2011 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELED PER 390-8637
05/16/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ENTIRE SERVICE HAS BEEN REPLACED 60 AMP FOR 60 AMP. PER TEP SPECS 2" RISER REQUIRED, BRACE RISER PER CODE OVER 30" IN HEIGHT
2) NEW PERMIT NEEDED FOR NEW DROP, CONTACT TEP FOR DIRECTION
3) STOPPED INSPECTION
05/12/2011 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) CALLED NUMBER LISTED ABOVE, NO CALL BACK
04/21/2011 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) ITEMS 1 2 5 7 HAVE BEEN CORRECTED
2) ITEM 3 4 8 NOT COMPLETE
04/09/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BROKEN RECEPTACLE
2) KITCHEN RECEPT TO BE GFCI PROTECTED
3) PLEASE VERIFY PERMIT FOR NEW WATER HEATER-ELECTRIC NOT WIRED
4) MISSING FURNACE
5) SMOKE DETECTORS NEEDED FOR BEDROOMS-INSTALL PER INSTRUCTIONS
6) EXPOSED NM WIRING IN SHED AND EXTERIOR OF HOUSE
7) SERVICE CONDUCTORS DAMAGED DUE TO FIRE