Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 03/16/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEPERATE GROUNDS AND NEUTRALS AT SUB PANEL 2) USE CORRECT BREAKER SIZED FOR CONDUCTOR AMPACITY-MAIN PANEL 3) NO GROUNDING ELECTRODE SYSTEM AT SERVICE 4) PLEASE VERIFY SERVICE UPGRADE PERMIT ] 5) NO GAS BOND PRESENT 6) GROUNDED RECEPTS ON ALL UNGROUNDED SYSTEM 7) EXPOSED ZIP CORD WIRING TO LIGHT 8) KITCHEN RECEPTS TO BE GFCI PROTECTED 9) EXPOSED NM CABLE FOR HOOD AND AT RANGE 10) PROTECT BULBS IN CLOSETS 11) SMOKE DETECTORS NEEDED IN BEDROOMS-INSTALL PER INSTRUCTIONS 12) EXPOSED CONDUCTORS IN CLOSET ABOVE SUB PANEL 13) COMBUSTION AIR REQUIRED FOR WATER HEATER, PLEASE VERIFY SERVICE AND QUALITY |