Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/28/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CEILING FANS NOT TO CODE-ZIP CORD IS NOT APPROVED METHOD TO WIRE FANS 2) SMOKE DETECTORS TO LOW-SHOULD BE 6"-12" BELOW CEILING FOR WALL MTD 3) A REINSPECTION FEE, NEXT INSPECTION IF NO COMPLIANCE |
|
| 04/01/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SMOKE DETECTORS WILL NOT WORK PROPERLY WHEN MTD. ABOVE AC REGISTER, SHOULD BE AT LEAST 3' AWAY OR PER MANUFACTURERS INSTRUCTIONS 2) ALSO BEDROOM CEILING FAN NOT WIRED PER CODE, ZIP CORD NOT APPROVED METHOD |
|
| 03/16/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PROTECTION FOR THE LIGHT BULB IN WALK IN CLOSET 2) PROVIDE GFI RECEPT AT KITCHEN COUNTER, REPLACE MISSING WALL COVER PLATE IN BEDROOM 3) PROVIDE SMOKE DETECTORS IN BEDROOMS 4) PROVIDE ACCESS TO WATER HEATER 5) WIRING FROM CARPORT LIGHT TO RECEPT NOT PER CODE 6) REPAIR BROKEN CONDUIT TO ELECTRIC DISCONNECT ON ROOF AND PROPERLY SUPPORT & SECURE DISCONNECT |