Permit: T10EL00465

Parcel: 113080430


Addresses:

2930 N MITCH DR


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T10EL00465

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/14/2010 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
04/12/2010 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/08/2010 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/29/2010 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO COMPLIANCE WITH NOTES #2,6,7 AND 8
2) ARC FAULTS NOT WORKING PROPERLY
3) A RE-INSPECTION FEE WILL BE ASSESSED NEXT INSPECTION IF NO COMPLIANCE
4) THESE NOTES ARE FOR BOTH UNITS 2930/2932
5) REMOVE CEILING FANS AND INSTALL APPROVED FAN BOXES
03/25/2010 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
LIST OF CORRECTIONS FOR BOTH ADDRESSES:
1) PLUG UNUSED OPENINGS IN SUB PANEL AND TERMINATE ROMEX CORRECTLY USING APPROVED CONNECTORS
2) USE RACE WAY CONTINOUS FOR PANEL FEEDERS
3) 110V CONV. RECEPTS NOT WIRED CORRECTLY
4) SEE NOTE #2 (3/4/10) DO THIS PRIOR TO NEXT INSPECTION
5) GFI RECEPTS NOT WORKING
6) HAVE ELECTRICIAN GO THRU ENTIRE AC SYSTEM, OUTLETS, FIXTURES, CHECK WIRING METHODS FOR CODE COMPLIANCE, MAKE CORRECTIONS AS NECESSARY RECALL INSPECTION. ELECTRICIAN TO PROVIDE INSPECTOR WITH SIGNED, NOTORIZED STATEMENT THAT A/C SYSTEM HAS BEEN CHECKED OUT COMPLETELY AND IS IN SAFE AND OPERATING CONDITION
7) OPEN 12" X 12" OPENING ABOVE RECEPTS THAT HAVE 2 WIRE SINGLE CONDUCTORS INSTEAD OF ROMEX
8) ARC FAULT PROTECTION IN BEDROOM CIRCUITS