Permit: T10EL00404

Parcel: 11007430A

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/01/2010 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
02/24/2010 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED.
2) BATHROOM RECEPTACLES TO BE GFI PROTECTED
3) INTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS. INSATLL SMOKE DETECTOR IN 1ST FLOOR.
4) INTALL MISSING WALL PLATES.
5) PROPERLY WIRE WATER HEATER CANNOT BE CORD & PLUG CONNECTED.
6) RESCHEDULE WHEN COMPLETE.