Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2010 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 03/23/2010 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/24/2010 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO INSTALL SMOKE DETECTORS IN BEDROOMS. 2) MISSING WALL PLATES ON DEVICES 3) KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED. 4) HAVE OPEN CONDUCTORS @ STOVE LOCATION & ABOVE KITCHEN SINK. 5) BLANK ALL OPEN JUNCTION BOXES 6) CONNECT EQUIPMENT GROUNDS TO JUNCTION BOX (ADD PANEL) IN LAUNDRY. 7) INSTALL SMOKE DETECTOR IN HALL OUTSIDE BEDROOMS 8) CHECK CABLES & POOL AREA IF LINE VOLTAGE OR FOR SPEAKERS. 9) BATHROOM RECEPTACLES TO BE GFI PROTECTED. 10) SEAL OPEN KNOCK OUTS. OK FOR 15 DAY RECONNECT. |