Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2010 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 03/08/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UNSAFE ELECTRICAL CONDITIONS STILL EXIST 2) VERIFICATION OF QUALIFIED ELECTRICIAN NOT EVIDENT 3) A REFEE MAY BE ASSESSED IF CORRECTIONS NOT COMPLETED |
|
| 03/03/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) CONDUIT FITTINGS AND WIRING METHODS TO BE FOR WET LOCATION 2) UNSAFE WIRING METHODS BEING USED-VERIFY QUALIFIED ELECTRICIAN PERFORMING WORK |
|
| 03/01/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) NO CIRCUITS CONNECTED TO THIS SERVICE 2) NEED PERMITS FOR WIRING TO THIS UNIT 3) PLEASE VERIFY PERMITS FOR CONVERSION TO DUPLEX FROM SINGLE RESIDENCE 4) FINISH PREVIOUS ITEMS 5) GROUND CLAMP TO GAS PIPE TO BE ON PIPE NOT UNION |
|
| 02/25/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO STRAP GROUNDING CONDUCTOR UNDER PANEL 2) NEED TO SEE PERMITS FOR INSIDE WORK 3) NEED WEATHER PROOF COVERS 4) NEED TO PUT ONLY ONE GROUNDING CONDUCTOR ON A CORN GROUND CLAMP-NOT TWO 5) NEED GROUND RODS BELOW GROUND LEVEL |