Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2011 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 09/08/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO WORK PROGRESS |
|
| 03/30/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINISH PREVIOUS ITEM 2, 5 & 6 |
|
| 03/11/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) SECURELY ATTACH BOX TO PANEL AND USE APPROVED FITTINGS 2) COVER TO BE WEATHER PROOF WETHER OR NOT PLUGGED INTO 3) NEED GAS AND WATER BONDS CONNECTED TO SERVICE 4) MAINTAIN WORKING SPACE BELOW PANEL-VEGITATION 5) A RECONNECT PERMIT MAY BE NEEDED BEFORE CONNECTION 6) NO POWER AT THIS TIME-NEED CROSSOVER DONE 7) OK GROUND RODS |