Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/01/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 02/19/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS LABEL ON ELECTRIC PANEL 2) MISSING SMOKE DETECTORS 3) M/C CABLING WIRIN IN GARAGE NOT TO CODE |