Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
02/25/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
1) ITEMS ON LIST OK
02/09/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) THIS IS A DUPLEX WITH A SINGLE SERVICE PANEL LABELING NOT CLEAR, AS TO WHICH UNIT AND WHAT THE BREAKERS CONTROL-BREAKER USED TO BE LISTED FOR USE BY MANUFACTURE-CHANGE PERMIT TO DUPLEX
2) USE CORRECT SIZE AMPACITY BREAKER FOR #8 NM CABLE
3) BASE BOARD HEATERS NOT LISTED AS CORD & PLUG AND ALSO ADD INSTALLATION TO PERMIT
4) OUTDOOR RECEPT AND SWITCH COVERS TO BE WEATHER PROOF AS PER 406.8
5) POST ADDRESS ON BLDG, UNITS AND PANEL
6) PLEASE VERIFY QUALIFIED ELECTRICIAN
7) PLEASE VERIFY PERMIT FOR NEW WATER HEATER
8) PLEASE VERIFY PERMIT FOR REMODELING AND NEW WIRING