Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
Permit Number - T10EL00205
Inspection Description - ELECTRIC - SERVICE UPGRADE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/08/2010 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
05/21/2010 | ELECTRIC - SERVICE UPGRADE | Partial Approval | IVRS - Inspection :* 1) STILL NEED MAIN BONDING JUMPER |
|
05/11/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) USE APPROVED TERMINATION LUGS AND TERMINALS 2) CANNOT USE THE TERMS GENERAL LIGHTS AND RECEPTS-LABEL AS PER 408.4 3) TAPE MARKINGS TO ENCIRCLE CONDUCTOR 4) FINISH PREVIOUS ITEMS |
|
05/03/2010 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) NEED PERMANENT METAL ADDRESS LABEL 2) NEED TO BOND SERVICE NIPPLE 250.92 3) GROUNDING ELECTRODE CONDUCTOR TO BE CONTINOUS 250.64 4) BOND SERVICE PANEL ENCLOSURE WITH MAIN BONDING JUMPER 5) LABEL CIRCUIT BREAKERS 6) UNGROUNDED CONDUCTORS TO BE IDENTIFIED 200.7 7) NEED GROUNDING ELECTRODE SYSTEM |