Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 01/27/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 2) BLANK OPEN BOX AT FIREPLACE AND WIRE NUT EXPOSED WIRES 3) INSTALL WALL PLATE ON RECEPT IN WATER HEATER CLOSET 4) BATHROOM RECEPT TO BE GFI PROTECTED 5) INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS 6) REMOVE NON CODE COMPLIANT WIRING AND FLOOD LIGHT IN BEDROOM 7) CANNOT USE FLEXIBLE CORD FOR PERMANENT WIRING TO DRYER RECEPTS 8) ROMEX CABLES RUN THRU METAL FRAMING TO BE PROTECTED BYN LISTED GROMMETS 9) VERIFY PERMITS FOR ADDITION AT EAST END, HAVE HAZARDOUS ELECTRIC AND PLUMBING. IT APPEARS ALSO NEW WASTE LINE INSTALLED ACROSS DRIVE WAY 10) ONE NEUTRAL PER TERMINAL AT PANEL 11) USE CONNECTORS AT PANEL AT WIRE ENTRY AND PROTECT ROMEX 12) BLANK OPEN BREAKER POSITIONS. USE BREAKER POSITIONS. USE BREAKERS LISTED FOR USE IN GE PANEL 13) VERIFY PERMITS FOR STRUCTURE BUILT ONTO REAR OF HOUSE, APPEARS TO BE NON-CODE COMPLIANT 14) PERMIT FOR NEW A/C ? 15) HAZARDOUS, NO RECONNECT |