Permit: T10EL00077

Parcel: 129055070


Addresses:

2951 E 17TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/27/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/19/2010 ELECTRIC - FINAL Denied 1) GROUNDED RECEPTS ON UNGROUNDED CIRCUITS
2) KITCHEN RECEPTS TO BE GFCI PROTECTED
3) BATHROOM RECEPT TO BE GFCI PROTECTED
4) INSTALL SMOKE DETECTORS 7"-9" DOWN FROM CEILING
5) CORRECTLY IDENTIFY UNGROUNDED CONDUCTORS AT PANEL EXTERIOR
6) SEAL ENTRANCE AT TOP OF PANEL WITH AN APPROVED FITTING
7) USE APPROVED TERMINAL CONNECTIONS AT PANEL INTERIOR