Permit: T10EL00064

Parcel: 136050420


Addresses:

9069 E 25TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
02/08/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
1) ITEMS ON LIST OK
01/19/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OPEN BOX WITH NON CODE COMPLIANT ZIP CORD UNDER ROOF EXE. CLOSE BOX AND REMOVE WIRING & INSTALL PER CODE
2) HAVE OPEN BOX AT FRONT OF HOUSE WITH NON CODE COMPLIANT WIRING
3) HAVE LIGHT FIXTURE AT FRONT OF HOUSE WITH IRRIGATION PIPING USED AS RACEWAY. INSTALL PER CODE OR REMOVE
4) HAVE OPEN BOX IN GARAGE
5) HAVE NON CODE COMPLIANT ZIP CORD USED FOR WIRING IN GARAGE
6) OUTDOOR RECEPTS TO BE GFI PROTECTED. RECEPTS IN GARAGE TO BE GFI PROTECTED
7) OUTDOOR RECEPTS TO HAVE WEATHER PROOF COVERS
8) INSTALL BREAKERS LISTED FOR USE IN SERVICE PANEL
9) ZIP CORD AND OPEN BOXES ALONG ENTIRE EXTERIOR OF HOME
10) TOO MANY VIOLATIONS ON EXTERIOR TO LIST
11) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED
12) INSTALL MISSING WALL PLATES AND INSTALL EXTENSIONS ON BOXES
13) REMOVE CORDS RUNNING THRU WALLS
14) BATHROOM RECEPTS TO BE GFI PROTECTED
15) NEED PANEL DIRECTORY
16) INSTALL SMOKE DETECTORS IN BEDROOMS
17) NEED TO HAVE QUALIFIED ELECTRICAL CONTRACTOR GO THRU ENTIRE HOME AND MAKE REPAIRS & REMOVE NON CODE COMPLIANT WIRING
18) RESCHEDULE WHEN COMPLETE