Case: T10DV06702

Parcel: 131120490


Addresses:

6001 E 32ND ST


Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T10DV06702

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
08/09/2013 INSP - FOLLOW UP CODE ENFORCE Approved Permit not finaled.
02/23/2012 INSP - FOLLOW UP CODE ENFORCE Approved No compliance on permits, both T11CM01464 and T05CM01050 expired. Met owner at property; rear yard storage is under 25% which is compliant. Photos.
02/16/2012 INSP - FOLLOW UP CODE ENFORCE Approved Unable to access property; photo.
11/28/2011 INSP - FOLLOW UP CODE ENFORCE Approved Site visit to reinspect storage and refuse in rear yard. Gate locked, no one home; unable to access or see rear yard; schedule appt w/ owner.
10/21/2011 INSP - FOLLOW UP CODE ENFORCE Approved Site visit with PDSD and HCDD personnel to assess second floor structural issues. See conditions for further info.
10/06/2010 INSP - FOLLOW UP CODE ENFORCE Approved Met property owner at site, who allowed access to his property. Further inspection of the main electrical panel required an immediate shut down of active electrical service due to hazardous conditions. TEP was contacted, concurred on the hazardous condition, and cut the power off at the pole. Reconnection of electrical will require an approved permit. Notice to Vacate was posted due to lack of electrical service and unpermitted construction that has not been approved; some may not be built to code. A stop work order was also posted. Owner will be issued a Notice requiring an approved permit that encompasses all the illegal work; anything that does not meet code will need to be removed. Electrical service must be repaired by a licensed contractor under permit. Owner will be allowed to reoccupy the premisis one these items are addressed. Please refer to NOV and photos.
10/05/2010 INSP - FOLLOW UP CODE ENFORCE Approved Observed main electrical panel in a hazardous condition, located on west side of building off the original structure. Breakers may be double lugged, appears to be ungrounded, several added wires/circuits coming out of panel in a haphazard manner not in conduit or in anyway according to accepted electrical code. Permit T05 for east and north side additions has expired without any inspections. Owner is now constructing a second story addition on top of these unapproved additions with no permit. No plans on file for the second story additions; will require a resubmittal and review. An attached ramada (actually 2 or 3 connected) to the rear property has also been built since the original plans were approved on
T05 and lack permits. Rear yard has a large amount of storage and refuse and exceeds 25% of lot, including several JMVs. Rear shed appears to have attached electrical.