Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T10DV06702
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2013 | INSP - FOLLOW UP CODE ENFORCE | Approved | Permit not finaled. | |
| 02/23/2012 | INSP - FOLLOW UP CODE ENFORCE | Approved | No compliance on permits, both T11CM01464 and T05CM01050 expired. Met owner at property; rear yard storage is under 25% which is compliant. Photos. | |
| 02/16/2012 | INSP - FOLLOW UP CODE ENFORCE | Approved | Unable to access property; photo. | |
| 11/28/2011 | INSP - FOLLOW UP CODE ENFORCE | Approved | Site visit to reinspect storage and refuse in rear yard. Gate locked, no one home; unable to access or see rear yard; schedule appt w/ owner. | |
| 10/21/2011 | INSP - FOLLOW UP CODE ENFORCE | Approved | Site visit with PDSD and HCDD personnel to assess second floor structural issues. See conditions for further info. | |
| 10/06/2010 | INSP - FOLLOW UP CODE ENFORCE | Approved | Met property owner at site, who allowed access to his property. Further inspection of the main electrical panel required an immediate shut down of active electrical service due to hazardous conditions. TEP was contacted, concurred on the hazardous condition, and cut the power off at the pole. Reconnection of electrical will require an approved permit. Notice to Vacate was posted due to lack of electrical service and unpermitted construction that has not been approved; some may not be built to code. A stop work order was also posted. Owner will be issued a Notice requiring an approved permit that encompasses all the illegal work; anything that does not meet code will need to be removed. Electrical service must be repaired by a licensed contractor under permit. Owner will be allowed to reoccupy the premisis one these items are addressed. Please refer to NOV and photos. | |
| 10/05/2010 | INSP - FOLLOW UP CODE ENFORCE | Approved | Observed main electrical panel in a hazardous condition, located on west side of building off the original structure. Breakers may be double lugged, appears to be ungrounded, several added wires/circuits coming out of panel in a haphazard manner not in conduit or in anyway according to accepted electrical code. Permit T05 for east and north side additions has expired without any inspections. Owner is now constructing a second story addition on top of these unapproved additions with no permit. No plans on file for the second story additions; will require a resubmittal and review. An attached ramada (actually 2 or 3 connected) to the rear property has also been built since the original plans were approved on T05 and lack permits. Rear yard has a large amount of storage and refuse and exceeds 25% of lot, including several JMVs. Rear shed appears to have attached electrical. |