Case: T10DV06332

Parcel: 129041750


Addresses:

2030 E BROADWAY BL


Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T10DV06332

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
02/29/2012 INSP - FOLLOW UP CODE ENFORCE Approved REINSPECTED SITE, SPACE STILL REMAINS EMPTY. NO ACTIVITY INSIDE SINCE 9/20/2010. ELECTRICAL COMPLETED UNDER PERMIT. HCDD HAS NO FURTHER JURISDICTION. COMPLIANCE / CLOSE CASE.
02/28/2011 INSP - FOLLOW UP CODE ENFORCE Approved F/U INSP FOUND STILL NO CHANGES. RESTARAUNT REMAINS CLOSED AND SECURED.
*SPOKE TO OWNER THOMAS UNGER WHO MENTIONED THEY HAVE NOT YET RECEIVED A CHECK FROM INSURANCE COMPANY TO MAKE NECESSARY REPAIRS AND IS UNSURE IF THE RESTARUANT OWNER WILL REOCCUPY, HAS NOT TALKED TO HIM IN SOME TIME. TRIED CONTACTING MANAGER WHO HAS NOT GOTTEN BACK WITH ME.
* SPOKE WITH CARLOS PORTILLO INFORMED HIM OF THE ABOVE INFORMATION CARLOS, ASKED THAT THE CASE BE PLACED IN OBSERVE STATUS WITH A 90 DAY F/U INSPECTION.
11/29/2010 INSP - FOLLOW UP CODE ENFORCE Approved F/U INSP FOUND BUILDIND STIL REMAINS UNOCCUPIED AND SECURED
10/21/2010 INSP - FOLLOW UP CODE ENFORCE Approved F/U INSP FOUND NO NEW WORK DONE TO THE STRUCTURE, STRUCTURE REMAINS SECURED. WILL FOLLOW UP IN ANOTHER 30 DAYS TO DETERMINE IF PERMITS FOR WORK AND C/O HAS BEEN SECURED.
10/06/2010 INSP - FOLLOW UP CODE ENFORCE Approved RECEIVED A CALL FROM THE ELECTRICAL CONTRACTOR THAT HE WAS READY TO REMOVE THE LOCKS ON THE DISCONNECTS THAT WERE LOCKED AT THE TIME OF THE FIRE. MET BOB FROM WIZARD ELECTRIC AND HE SHOWED ME THE WORK DONE TO REMOVE THE BUNED WIRES IN THE WALL BEHIND THE HOOD SYSTEM. THE LOCKS WERE REMOVED AND THE ELECTRICIAN WAS GOING TO REMOVE THE FUSES UNTIL THE OTHER REPAIRS ARE COMPLETED AND READY FOR AN INSPECTION. THIS CASE WILL BE GIVEN TO GERALD DUE TO IN HIS AREA. HE WAS AT THE SITE TO SEE WHERE THE FIRE WAS AND LOOK AT THE DAMAGE. WILL KEEP THE SAME FOLLOW DATE FOR THE NEXT INSPECTION. RV.
10/06/2010 INSP - FOLLOW UP CODE ENFORCE Approved MET WITH RICHARD VIDAL AND ELECTRICAL CONTRACTOR BOB BLIZZARD. RICHARD REMOVED LOCKS FOR THE ELECTRICIAN WHO IN TURN REMOVED HAZARDOUS ELECTRICAL INSIDE THE PANEL AND IN THE INTERIOR OF THE STRUCTURE. BOB INDENTIFIED WIRING INSIDE THAT NEEDED TO BE REMOVED. ELECTRICIAN ALSO SECURED PERMIT FOR NEW TEMP POWER AND MENTIONED FUSES WOULD BE LEFT OUT OF THE PANEL UNTIL DRAWINGS FOR NEW WORK WAS COMPLETED AND NEW ELECTRICAL WORK TO BEGIN.