Case: T10DV05718

Parcel: 117143190


Addresses:

541 S MAIN AV


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T10DV05718

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
09/13/2010 INSP - INITIAL CODE ENFORCMENT Approved THIS ADOBE STRUCTURE IS IN A DILAPIDATED AND A DETERIORATING STATE, THE STRUCTURE LACKS WINDOW AND DOOR OPENINGS. THE ROOF STRUCTURES WOOD MEMBERS ARE DETERIORATED AND HAVE WOOD ROT DUE TO THE LACK OF ANY ROOF COVERING SYSTEM. THE ROOF TRUSSES ARE BEARING ON THE ADOBE EXTERIOR WALLS WHICH HAVE SEVERE CRACKING. PORTIONS OF THE BEARING WALL HAVE HAD PIECES OF THE ABODE THAT HAVE DISLODGED AT THE TRUSS BEARING POINT. THE SOUTH SIDE OF THE BEARING WALL HAS HAD A SECTION OF 10 FOOT BY 8 FOOT THAT HAS COLLAPSED WHICH HAS CAUSE THE ROOF SYSTEM TO SAG TO AN UNSUPPORTED STATE. THE REAR SECTION OF THE DWELLINGS FLAT ROOF SYSTEM IS BEING SUPPORTED BY A BEAM AND 3 POSTS DUE AN INTERIOR WALL THAT HAS COLLAPSED, IN THIS AREA WHERE THE GABLE ROOF MEETS THE FLAT ROOF SYSTEM THERE IS NO ROOF PROTECTION. SOME OF THE TRUSS MEMBERS HAVE SEPARATED AT MID POINT. THE INTERIOR OF THE STRUCTURE HAS NO FINISH ON THE WALLS OR CEILINGS. THE FLOOR IS DIRT, NO SUB FLOORS. THE ENTIRE INTERIOR HAS BEEN GUTTED TO THE ADOBE WALLS. THE EXTERIOR WALLS HAVE SEVERE CRACKS AND WHERE THE WALLS MEET THE FOUNDATION THERE ARE SECTIONS OF MISSING ADOBE WALL. HISTORICAL ZONE