Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2010 | INSP - INITIAL CODE ENFORCMENT | Approved | HOUSE FIRE IN BEDROOM, THERE IS A 4 X 6 FOOT CUT OUT OF THE ROOF SHEATHING. DAMAGE TO 10 FOOT SECTION OF THE EAVE AREA TO INCLUDE RAFTERS TAIL, BIRDS BOARD AND ROOF SHEATHING WITH ALLIGATORING, ONE 3 X 4 WINDOW IS DAMAGED AND WAS BOARDED. INTERIOR OF THE DWELLING HAS OVER 200 SQUARE FEET DRYWALL DAMAGE. 3 INTERIOR DOORS ARE DAMAGED, BEDROOM RECEPTACLES, WALL LIGHT AND THE THERMOSTAT CONTROLLER IN THE HALLWAY HAVE HEAT DAMAGE. SMOKE DAMAGE TO THE INTERIOR OF THE DWELLING. THE ELECTRIC METER WAS BOOTED OFF BY TEP, THE GAS METER WAS SHUT OFF PRIOR TO THE FIRE. THE DISCONNECT HAS TWO NEW CIRCUITS THAT WERE ADDED WITHOUT PERMITS ONE TO A DRYER AND ONE TO A ROOF TOP A/C UNIT. SCHEDULE UP INSPECTION FOR 90 DAYS OUT |