Case: T10DV03763

Parcel: 13626007C


Addresses:

3480 S MANN AV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
06/08/2010 INSP - INITIAL CODE ENFORCMENT Approved EMERGENCY CALL OUT BY TFD, HOUSE FIRE
DAMAGE TO ROOF AREA SECTIONS WERE CUT OUT AS FOLLOWS:
(2) 4X4 SECTIONS (1) 4 X 15 FOOT SECTION. 2X8 RAFTERS SHOW SEVERE ALLIGATORING IN THE KITCHEN AND LAUNDRY ROOM CARPORT AREA. LAUNDRY ROOM HAS DAMAGE EXTERIOR SIDING, AND STUDS. THERE IS A 2 X 8 X 20 MADE BEAM WITH SEVERE ALLIGATORING AND CHARRING IN CARPORT AREA. THE WOOD MEMBERS IN THE HALLWAY THAT SUPPORT THE DUCT WORK ARE SAGGING. INTERIOR DAMAGE IN THE LIVING ROOM KITCHEN AND BEDROOM CEILINGS ARE IS EXTENSIVE DAMAGE TO THE DRYWALL IN THE THESE AREAS. INSPECTION CUT OUT IN THE BATHROOM AND REAR BEDROOM AND HALLWAY AREA.

THESE AREAS ALSO HAVE BARE WIRING FROM FIXTURES AND DEVICES.
THE METER TO THE MAIN DISCONNECT WAS BLOCKED BY TEP, SWG PINNED THE METER OFF.

DUCT IN THE ROOF FROM THE COOLER WAS DAMAGED, SEVERE SMOKE DAMAGE IN THE INTERIOR. PERMITS REQUIRED TO REHABILITATE THE DWELLING. THE DWELLING WAS POSTED UNFIT TO OCCUPY AND CONDEMNED.
ASSIGN CASE TO AREA INSPECTOR FOLLOW UP INSPECTION DUE WITHIN 90 DAYS