Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/09/2010 | INSP - INITIAL CODE ENFORCMENT | Approved | FIRE DAMAGE TO REAR UTILITY ROOM, STRUCTURE IS WOOD FRAME THERE WAS DAMAGE TO ALL THE INTERIOR FINISH (PLASTER) TO THE WALLS AND CEILING. THE CEILING JOIST AND WALL STUDS WERE BURNT, ONE STUD IS CHARRED AND SHOW SIGNS OF ALLIGATORING, ONE TRIMMER STUD (ATTIC) ALSO BADLY BURNT AND CHARRED. THE ROOF SHEATHING WAS DAMAGE AT THE SOUTHWEST CORNER OF THE ROOF. TWO WINDOW OPENINGS AND ONE DOOR OPENING WERE DAMAGED. THERE WAS SEVERE SMOKE DAMAGE TO INTERIOR OF THE DWELLING. THE FLEX DUCT WORK IN ATTIC HAS MELTED. THE UTILITY ROOM WAS BOARDED BY CONTRACTOR BATHCREST. MAIN DWELLINGS ELECTRICAL METER WAS PULLED. BARE EXPOSED CONDUCTORS IN THIS AREA WERE PRESENT. LIGHT FIXTURE AND WALL RECEPTACLES WERE DAMAGED. SOUTHWEST GAS TURNED GAS OFF TO THE METER. THE DWELLING WAS CONDEMNED AND POSTED UNSAFE TO OCCUPY |