05/20/2015 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
04/06/2015 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* | |
04/06/2015 | BUILDING - FINAL | Partial Approval | 1. PROVIDE LETTER OF COMPLIANCE FROM PLUMBER 2. EXPOSE FOOTERS AT GARAGE/WORKSHOP |
|
05/13/2014 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
05/13/2014 | BUILDING - FINAL | Not ready for Inspection | 1. ALL WORK IS COMPLETED. PROVIDE DOCUMENTATION FROM LICENSED ELECTRICAL & PLUMBING CONTRACTORS. ALSO, EXPOSE FOOTERS, EXPOSE RAFTER CONNECTIONS, ETC.. 2. JOIST SUPPORT NOT PER PLAN SEE DETAIL 6 PAGE 5 |