Permit: T10CM03492

Parcel: 10707003H


Addresses:

2727 N FAIRVIEW AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T10CM03492

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
07/29/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ONLY ONE SLIP NUT ALLOWED ON THE DISCHARGE SIDE OF THE TRAP
2) IW PIPING BETWEEN 5'-15' REQUIRED TO BE ? TRAPPED-NO VENT REQUIRED
3) PVC REQUIRES PRIMER AS WELL AS SOLVENT CEMENT
07/25/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
07/07/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SEE BLUE CIRCLED NOTES ON KITCHEN GENERAL NOTES
2) SEE BLUE CIRCLED NOTES ON PLUMBING SPECS
3) NOT INSTALLED PER PLAN